INDUSTRIAL SIGNAL CONDITIONING & PRECISION DAQ[email protected]
∿LOADCELLAMPLIFIERSmV/V TO MEANINGFUL DATA
Amplifiers by OutputComparison GuideFUTEK & HBM ReplacementIndustrial Upgrade
Request Quote ↗
LoadCellAmplifiers.com

An Industrial Signal Conditioning & Precision DAQ Division of Magatom Dynamics Co., Ltd.

Shenzhen, China · Industrial B2B supply

[email protected]
Signal interfacesAnalog / DIN railUSB / PC acquisition2 / 4 / 6 / 8 cell summingCompact / in-line cableIndependent channels / fieldbus
Engineering & CompanyAboutRequest Quote / SampleModule Comparison GuideIndustrial HX711 Upgrade
© 2026 LoadCellAmplifiers.com
PrivacyTermsCookies

SIGNAL CONDITIONING / MT-AMP-BUS

Multi-Channel RS485 & EtherCAT Digitizers

Read separate load cell channels for force balance, eccentric load monitoring and automation. Request the exact protocol and timing behavior your controller requires.

Request Model & Sample Review ↗

MT-AMP-BUS Series

Bridge input
Per-channel bridge input
Output options
RS485 Modbus RTU / CANopen / EtherCAT options
Acquisition / bandwidth
Rate & synchronization to confirm
Channel architecture
1 / 4 / 8 independent
Enclosure
Industrial DIN rail
Typical application
Multi-axis force control, independent corner monitoring and PLC networks
Replacement evaluation
HBM ClipX / PMX · Siemens SIWAREX

This is a family selection specification. Target values are not a released model datasheet. Exact performance, approval status, software, stock and delivery require a written quotation.

SIGNAL CHAIN / MT-AMPmV/V → ENGINEERING DATA
MT-AMPFULL BRIDGECONDITIONERPLC / SCADA0–10V / 4–20mAPC / FIELDBUSUSB / RS485 / EtherCAT

Functional signal path schematic · configuration depends on model

Before you select a model

  1. Select one protocol and confirm device description files.
  2. Specify per-channel sample rate, bus cycle and synchronization.
  3. Confirm register mapping, diagnostics and channel isolation.

SELECTION MATRIX

Load Cell Amplifier Comparison Table

Start with the output your system needs.
Then check the complete signal chain.

MT-AMP family planning matrix. Values marked target require model-specific confirmation.
ModelInput Range (mV/V)Output SignalSampling Rate / BandwidthChannelsEnclosureReplacement Review
MT-AMP-DIN ↗0.5–4.0 mV/V target0–5V, 0–10V, ±5V, ±10V, 4–20mAAnalog bandwidth 1–5 kHz target135 mm DIN rail / aluminumFUTEK IAA100 / IAA200 · HBM RM4220 · Burster 9235
MT-AMP-USB ↗mV/V range to confirmUSB to PC · CSV logging requirementUp to 4,800 samples/s target1USB-C / aluminumFUTEK USB220 · Mantracourt DSCUSB
MT-AMP-SUM ↗Matched bridge sensorsSummed mV/V · optional 4–20mA / RS485Passive: no sampling rate2 / 4 / 6 / 8 → 1304 / 316 stainless · IP67 targetHBM VKK · Rice Lake · AnyLoad J-box
MT-AMP-INL ↗mV/V range to confirm0–5V, 0–10V, 4–20mA or RS485 optionsBandwidth to confirm1Ø12 × 55 mm tube / IP67 targetFUTEK ICA family · Interface in-line amplifiers
MT-AMP-BUS ↗Per-channel bridge inputRS485 Modbus RTU / CANopen / EtherCAT optionsRate & synchronization to confirm1 / 4 / 8 independentIndustrial DIN railHBM ClipX / PMX · Siemens SIWAREX

Analog bandwidth and digital sample rate are different quantities. Passive summing boxes do not sample. Named manufacturers are comparison references; electrical, mechanical, software and calibration equivalence requires review.

BRIDGE COMPATIBILITY

4-wire or 6-wire?
Start at the bridge.

Match terminals by function and the sensor datasheet. Wire colors and connector pinouts vary by manufacturer.

A 6-wire connection measures excitation at the bridge through separate sense leads. A 4-wire sensor uses excitation and signal pairs; follow the amplifier manual for local sense links.

Strain gauge full bridgeAmplifier input
+ExcitationE+
−ExcitationE−
+SignalS+
−SignalS−
+SenseSEN+
−SenseSEN−

Dashed sense lines: 6-wire option. On a 6-wire sensor feeding a 4-wire input, the sensor manual may require sense-to-excitation links of matching polarity. Never infer pin numbers or wire colors.

ENGINEERING / RFQ

Tell us what
your PLC needs.

Share your sensor sensitivity, interface and acquisition speed. We will review the bridge, signal chain and integration requirements before quoting.

[email protected]
Sensor + amplifier bundles

Request a complete measurement chain and 5-point system calibration. Include the sensor capacity, force direction and acceptance criteria.

Complete your measurement chain

By submitting, you agree to our privacy policy. Options, pricing, calibration scope and delivery are confirmed in your quotation.