INDUSTRIAL SIGNAL CONDITIONING & PRECISION DAQ[email protected]
∿LOADCELLAMPLIFIERSmV/V TO MEANINGFUL DATA
Amplifiers by OutputComparison GuideFUTEK & HBM ReplacementIndustrial Upgrade
Request Quote ↗
LoadCellAmplifiers.com

An Industrial Signal Conditioning & Precision DAQ Division of Magatom Dynamics Co., Ltd.

Shenzhen, China · Industrial B2B supply

[email protected]
Signal interfacesAnalog / DIN railUSB / PC acquisition2 / 4 / 6 / 8 cell summingCompact / in-line cableIndependent channels / fieldbus
Engineering & CompanyAboutRequest Quote / SampleModule Comparison GuideIndustrial HX711 Upgrade
© 2026 LoadCellAmplifiers.com
PrivacyTermsCookies

SIGNAL CONDITIONING / MT-AMP-INL

In-Line Cable Amplifiers & Signal Boosters

Condition the low-level bridge signal close to the sensor, then route an amplified signal through the machine. Select the output around cable length and receiver requirements.

Request Model & Sample Review ↗

MT-AMP-INL Series

Bridge input
mV/V range to confirm
Output options
0–5V, 0–10V, 4–20mA or RS485 options
Acquisition / bandwidth
Bandwidth to confirm
Channel architecture
1
Enclosure
Ø12 × 55 mm tube / IP67 target
Typical application
Robotic tooling, compact equipment and remote sensor wiring
Replacement evaluation
FUTEK ICA family · Interface in-line amplifiers

This is a family selection specification. Target values are not a released model datasheet. Exact performance, approval status, software, stock and delivery require a written quotation.

SIGNAL CHAIN / MT-AMPmV/V → ENGINEERING DATA
MT-AMPFULL BRIDGECONDITIONERPLC / SCADA0–10V / 4–20mAPC / FIELDBUSUSB / RS485 / EtherCAT

Functional signal path schematic · configuration depends on model

Before you select a model

  1. Check available supply and allowable cable voltage drop.
  2. Define connector pinout, shielding and mounting clearance.
  3. Validate bandwidth and noise over the actual cable run.

SELECTION MATRIX

Load Cell Amplifier Comparison Table

Start with the output your system needs.
Then check the complete signal chain.

MT-AMP family planning matrix. Values marked target require model-specific confirmation.
ModelInput Range (mV/V)Output SignalSampling Rate / BandwidthChannelsEnclosureReplacement Review
MT-AMP-DIN ↗0.5–4.0 mV/V target0–5V, 0–10V, ±5V, ±10V, 4–20mAAnalog bandwidth 1–5 kHz target135 mm DIN rail / aluminumFUTEK IAA100 / IAA200 · HBM RM4220 · Burster 9235
MT-AMP-USB ↗mV/V range to confirmUSB to PC · CSV logging requirementUp to 4,800 samples/s target1USB-C / aluminumFUTEK USB220 · Mantracourt DSCUSB
MT-AMP-SUM ↗Matched bridge sensorsSummed mV/V · optional 4–20mA / RS485Passive: no sampling rate2 / 4 / 6 / 8 → 1304 / 316 stainless · IP67 targetHBM VKK · Rice Lake · AnyLoad J-box
MT-AMP-INL ↗mV/V range to confirm0–5V, 0–10V, 4–20mA or RS485 optionsBandwidth to confirm1Ø12 × 55 mm tube / IP67 targetFUTEK ICA family · Interface in-line amplifiers
MT-AMP-BUS ↗Per-channel bridge inputRS485 Modbus RTU / CANopen / EtherCAT optionsRate & synchronization to confirm1 / 4 / 8 independentIndustrial DIN railHBM ClipX / PMX · Siemens SIWAREX

Analog bandwidth and digital sample rate are different quantities. Passive summing boxes do not sample. Named manufacturers are comparison references; electrical, mechanical, software and calibration equivalence requires review.

BRIDGE COMPATIBILITY

4-wire or 6-wire?
Start at the bridge.

Match terminals by function and the sensor datasheet. Wire colors and connector pinouts vary by manufacturer.

A 6-wire connection measures excitation at the bridge through separate sense leads. A 4-wire sensor uses excitation and signal pairs; follow the amplifier manual for local sense links.

Strain gauge full bridgeAmplifier input
+ExcitationE+
−ExcitationE−
+SignalS+
−SignalS−
+SenseSEN+
−SenseSEN−

Dashed sense lines: 6-wire option. On a 6-wire sensor feeding a 4-wire input, the sensor manual may require sense-to-excitation links of matching polarity. Never infer pin numbers or wire colors.

ENGINEERING / RFQ

Tell us what
your PLC needs.

Share your sensor sensitivity, interface and acquisition speed. We will review the bridge, signal chain and integration requirements before quoting.

[email protected]
Sensor + amplifier bundles

Request a complete measurement chain and 5-point system calibration. Include the sensor capacity, force direction and acceptance criteria.

Complete your measurement chain

By submitting, you agree to our privacy policy. Options, pricing, calibration scope and delivery are confirmed in your quotation.